Page 1 - THE ASTRO LINE SERIES

THE ASTRO LINE SERIESGEMINI 5200 INSTRUCTION MANUALGEM52-wip.QXD 4/13/05 11:52 AM Page 1

Page 2 - INTRODUCTION

INPUT CIRCUITRY & SET-UPThere are two independent input channels on the Gemini 5200. Various typesof sensor outputs can be accommodated by appropr

Page 3 - TABLE OF CONTENTS

PROGRAMMING THE GEMINI 5200 IN DUAL RATE WITHOUT DISPLAY C MODEThe rate indicators use a time interval method (1/tau) to calculate the ratevalue. This

Page 4 - GENERAL DESCRIPTION

CODE 44 - RATE B MINIMUM/MAXIMUM UPDATE TIMEThe determination of the rate value uses a method in which the elapsed time ismeasured between the first a

Page 5 - TIMED OUTPUT VALUES

CODE 52 - OUTPUT 1 TERMINATION MODESThe Gemini 5200 has four “Output 1 termination Modes” which control theway Output 1 will terminate or reset. In al

Page 6 - TIMED OUTPUT VALUES [Cont’d]

CODE 54 - OUTPUT 2 TERMINATION MODES (Cont’d)[54 3] TERMINATE AT MANUAL RESET - Output 2 activates when the rate isgreater than or equal to the Preset

Page 7 - FACTORY SETTINGS

CODE 63 - RATE A MINIMUM/MAXIMUM UPDATE TIMEThe determination of the rate value uses a method in which the elapsed time ismeasured between the first a

Page 8 - FACTORY SETTINGS [Cont’d]

CODE 66 - “OPERATOR ACCESSIBLE FUNCTIONS” MODES (Cont’d)[66 -1][66 -2] These Modes are the same as above with the[66 -3] exception that manual reset i

Page 9 - PROGRAMMING DISABLED

PROGRAMMING THE A/B, (A-B)/B, AND A-B DISPLAY C MODESThis section will deal with the programming and operation of the Gemini 5200in the modes which in

Page 10 - OVERFLOW INDICATION

CODE 42 - RESET BUTTON & TERMINAL ACTUATIONMODESThe Reset Button & Terminal Actuation modes control the effect that the resetbutton and termin

Page 11 - CODE 41 - UNIT PERSONALITY

Note: When Preset tracking is enabled, before changing Preset 2 via serialcommunications, the Preset 2 value must be interrogated in order to establis

Page 12 - CODE 51 - OUTPUT ASSIGNMENT

INTRODUCTIONThe Gemini 5200 is another unit in a multi-purpose series of industrialcontrol products that are field-programmable to solve multiple appl

Page 13

CODE 54 - OUTPUT 2 TERMINATION MODESThe Gemini 5200 has four “Output 2 termination Modes” which control theway Output 2 will terminate or reset. In al

Page 14

CODE 62 - RATE A CONVERSION FACTORThe Rate A Conversion Factor is used to convert Display A to indicate rate inthe desired time unit. See Appendix “F”

Page 15

CODE 66 - “OPERATOR ACCESSIBLE FUNCTIONS” MODESThe Gemini 5200 has four basic levels of “Operator Accessible Functions”.Each of these levels can be mo

Page 16 - SCALE FACTORSA&B

GEMINI 5200 PROGRAMMING EXAMPLE - SPEED RATIOA paper towel manufacturer needs to maintain a tight control on the speedrelationship of two rollers. Two

Page 17 - BASIC OPERATION

SCALING DISPLAY CScaling Display C is simply a matter of choosing the amount of decimal pointresolution that is desired for the application. This is a

Page 18

GEMINI 5200 20 MA CURRENT LOOP COMMUNICATIONSThe Gemini 5200’s 20 mA Current Loop Communications Option allows a“two-way” serial communications link t

Page 19

SENDING COMMANDS & DATA TO THE GEMINI 5200When sending commands to the Gemini 5200, a command string must beconstructed. The command string may co

Page 20

SENDING COMMANDS & DATA TO THE GEM52 [Cont’d]As shown, all commands must be terminated with a “Command Terminator”(*or 2AH). The Gemini 5200 will

Page 21

RECEIVING DATA FROM THE GEMINI 5200Data is transmitted from the Gemini 5200 when a “Transmit Value” or“Transmit per Print Options” command is sent to

Page 22

CURRENT LOOP INSTALLATIONWIRING CONNECTIONSWhen wiring the 20 mA current loop, remove the 7-position terminal block(TBD), located on the right side of

Page 23 - SCALING THE RATE CHANNELS

-1-TABLE OF CONTENTSI. GENERAL DESCRIPTION 2A) Safety Summary2B) Programming The Gemini 52002C) Programming The Personality2D) Programming The Presets

Page 24 - HARDWARE SET-UP

COMMUNICATIONS APPLICATION-28-Note: A Serial Converter Moduleis available for interfacing anRS232 device to Geminis.PROCESS MONITORING SYSTEMFive Gemi

Page 25 - COMMUNICATION FORMAT

TROUBLESHOOTING GEMINI SERIAL COMMUNICATIONSIf problems are encountered when trying to get the Gemini(s) and host device orprinter to communicate, the

Page 26

APPENDIX “A” - INSTALLATION & INPUT CONFIGURATION SWITCH SET-UPBefore installing the Gemini 5200 into the panel, the user should first becomefamil

Page 27 - FIG. 3: RESET COMMAND TIMING

SELECT AC POWER (115/230 VAC)The AC power to the unit must be selected for either 115 VAC or 230 VAC.The selector switch is located through an access

Page 28 - PRINT OPTIONS

ADDITIONAL EMC INSTALLATION GUIDELINESAlthough this unit is designed with a high degree of immunity toElectroMagnetic Interference (EMI), proper insta

Page 29 - SERIAL DIP SWITCH SET-UP

PRIMARY A.C. WIRINGFor best results, the A.C. primary power should be relatively “clean” and withinthe specified +/-10% variation limits. Drawing powe

Page 31 - SERIAL LOOP-BACK SELF-TEST

-35-CONNECTIONS & CONFIGURATION SWITCH SET-UPS FOR VARIOUS SENSOR OUTPUTS (See Note 5)

Page 32 - Installation Environment

Notes:1. SENSOR VOLTAGE AND CURRENTThe +12 V sensor supply voltage on the “DC OUT” terminal is nominal with+/-25% variation due to line and internal l

Page 33 - SHIELD TERMINATION

SENSOR INPUT CONNECTIONS & INPUT CONFIGURATIONSWITCH SET-UPThe accompanying diagram shows the details of the logic and magneticpickup circuitry. T

Page 34

GENERAL DESCRIPTIONThe Gemini 5200 is a multi-function dual rate indicator which can fulfillalmost any rate indication application. The unit can opera

Page 35 - SERIAL COMMUNICATIONS

APPENDIX “B” - SPECIFICATIONS & DIMENSIONS1. DISPLAY: 6-digit 0.56" (14.2 mm) High LED display.2. POWER REQUIREMENTS:AC Power: Switch selecta

Page 36 - BLOCK DIAGRAM

11. SERIAL COMMUNICATIONS:Type - Bi-directional 20 mA current loop, 20 mA source provided. (Powers upto 7 units in a loop with internal current source

Page 37

APPENDIX “C” - TROUBLESHOOTING GUIDE-40-The majority of difficulties arising with the Gemini 5200 are related to incorrect hook-upand programming set-

Page 38

-41-APPENDIX “C” - TROUBLESHOOTING GUIDEPROBLEM POSSIBLE CAUSE REMEDIESINCORRECT RATE READING 1. Input type incorrectly selected. 1. Check rear panel

Page 39 - SWITCH SET-UP

-42-APPENDIX “D” - GEMINI 5200 DUAL RATE W/O DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS41 UNIT PERSONALITY (-)Loads factory se

Page 40 - DIMENSIONS In Inches (mm)

-43-APPENDIX “D” - GEMINI 5200 DUAL RATE W/O DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS46 RATE B DECIMAL POINT & LEAD ZERO

Page 41

-44-APPENDIX “D” - GEMINI 5200 DUAL RATE W/O DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS56 RATE B RIGHT-HAND DUMMY ZEROS1 1 Dum

Page 42

-45-APPENDIX “D” - GEMINI 5200 DUAL RATE W/O DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS65 RATE A DECIMAL POINT & LEAD ZERO

Page 43

-46-APPENDIX “E” - GEMINI 5200 DUAL RATE W/ DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS41 UNIT PERSONALITY (-)Loads factory set

Page 44

-47-APPENDIX “E” - GEMINI 5200 DUAL RATE W/ DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS46 DISPLAY C DECIMAL POINT & LEAD ZE

Page 45

Pressing the “E” key finalizes the change. The displaywill now show the rate value immediately.If you do not press the “E” key, the change will not be

Page 46

-48-APPENDIX “E” - GEMINI 5200 DUAL RATE W/ DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS55 TIMED OUTPUT 2 VALUE Range 0.01 to 59

Page 47

-49-APPENDIX “E” - GEMINI 5200 DUAL RATE W/ DISP C FUNCTION COMMAND CODE SUMMARYCODE MODE DESCRIPTION COMMENTS65 RATEA&BDECIMAL POINT & LEAD Z

Page 48

APPENDIX “F” - SCALING FOR RATE & DISPLAY CThe Gemini 5200 offers a simplified method of scaling the rate indicator. Themethod does not require ti

Page 49

In situations where the Total Scale Factor is already in range of the ScaleFactor (0.0001 to 5.9999) and when there are no significant digits lost, th

Page 50

RATE SCALING EXAMPLES (Cont’d)We now have all the information necessary to scale the rate. The Total ScalingFactor “KT”, is calculated using Formula #

Page 55

-57-APPENDIX “H” - ORDERING INFORMATIONMODEL NO. DESCRIPTION W/20 mA Current LoopPART NUMBERS115/230 VACGEM52 Gemini 5200 No GEM52060Yes GEM52160¾Gemi

Page 56

PROGRAMMING THE PRESETS, SCALE FACTORS &TIMED OUTPUT VALUES [Cont’d]Note: A Timed Output Value of zero cannot be programmed into the Gemini5200. I

Page 57

-58-This page is intentionally left blank.

Page 58

-59-This page is intentionally left blank.

Page 59

-60-This page is intentionally left blank.

Page 60

LIMITED WARRANTYThe Company warrants the products it manufactures against defects inmaterials and workmanship for a period limited to one year from th

Page 61

GEM52 / IM - I 4/05DRAWING NO. LP0161Red Lion Controls 20 Willow Springs CircleYork PA 17402Tel +1 (717) 767-6511Fax +1 (717) 764-0839Red Lion Con

Page 62

FACTORY SETTINGSINITIAL FACTORY CONFIGURATION (DUAL RATE)Keys Struck Display Description4,1 41 1 Personality selected as DUAL RATE W/O DISP C4,2 42 3

Page 63 - LIMITED WARRANTY

FACTORY SETTINGS [Cont’d]DUAL RATE WITH SPEED DIFF. FACTORY SETTINGS *Keys Struck Display Description4,1 41 3 Personality selected as DUAL RATE W/SPEE

Page 64 - DRAWING NO. LP0161

OPERATOR ACCESSIBLE FUNCTIONS WITHPROGRAMMING DISABLEDOne of the important features of the Gemini 5200 is the ability to disableprogramming. With this