3-WAY ISOLATION OF ANALOG SIGNALS
UNIVERSAL CONVERSION MODULE - INPUTS AND OUTPUTS
SELECTED VIA DIP SWITCH SETTINGS
OVER 100 INPUT AND OUTPUT ANALOG CONVERSION
COMBINATIONS
CHOOSE LINEAR OR SQUARE ROOT EXTRACTION MODEL
ALL RANGES ARE FACTORY PRECALIBRATED. CUSTOM FIELD
CALIBRATION IS AVAILABLE FOR ALL RANGES WHILE
MAINTAINING THE FACTORY CALIBRATION FOR FUTURE USE
11 to 36 VDC AND 24 VAC MODULE POWER
GENERAL DESCRIPTION
The IAMA – Universal Signal Conditioning Module Series can isolate and
convert over 100 combinations of analog signal ranges. The IAMA3535
converts and transmits signals linearly proportional to the input, while the
IAMA6262 transmits the scaled square root of the input signal. This allows the
IAMA6262 to provide a signal that is linear to flow rate in applications utilizing
a differential pressure transducer.
DIP switch range selection eliminates the need to order and stock different
modules for each input and output signal range, and allows quick and
convenient setup for over 100 standard signal conversions. By utilizing the
Field mode of calibration, the user can customize the input and output scaling
for odd applications, including reversal of the output relative to the input.
In addition to the conversion capabilities, the IAMA modules feature
optically isolated Input/Output signal circuits and transformer isolated Power to
Input, Power to Output circuits.
The modules’ overall full scale accuracy typically exceed 0.05% depending
upon range selection and scaling. The microprocessor based design provides
ease of field scaling and the onboard E
2
PROM stores scaling values for future
recall. Both models come factory precalibrated for all input and output ranges.
Factory or custom field scaling can be selected by a simple mode switch change.
The IAMA can be factory recalibrated in the field if desired.
The modules’ environmental operating temperature range is -20°C to +65°C.
DIN rail mounting saves time and panel space. The units are equipped with
universal mounting feet for attachment to standard DIN style rails, including top
hat profile rail according to EN50022 - 35x7.5 and 35 x 15 and G profile rail
according to EN50035-G32.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
IAMA
Linear Universal Signal Conditioning Module IAMA3535
Square Root Universal Signal Conditioning Module IAMA6262
SPECIFICATIONS
1. POWER: 11 to 36 VDC, 3 W max. or 24 VAC, ±10%, 50/60 Hz, 4.8 VA max.
2. INPUT/OUTPUT RANGES: See Tables 2 and 3
3. ZERO/SPAN ADJUSTMENTS: Digital (DIP Switch Transition)
4. MAX INPUT SIGNAL:
Current Input: 110 mA DC, 1.1 VDC
Voltage Inputs: Terminal 7- 1 VDC +10%
Terminal 8- 10 VDC +10%
Terminal 9- 100 VDC +10%
5. INPUT RESISTANCE:
Current: 10
Voltage: > 100 K
6. INPUT PROTECTION: Surge suppressor diodes
7. OUTPUT: Self-powered (Active)
8. MAX OUTPUT CURRENT:
Current Output: 22 mA
Voltage Output: 10 mA
9. LOAD RESISTANCE:
Current Output: 600
Voltage Output: 1 K
10. OUTPUT COMPLIANCE:
Current: 4 to 20 mA, 0 to 20 mA: 12 V min ( 600 )
0 to 1 mA: 10 V min (10 K)
Voltage: 10 VDC across a min. 1 K load (10 mA). Factory calibrated for
loads of > 1 M.
11. ISOLATION LEVEL INPUT TO OUTPUT: 1.5 kV @ 50/60 Hz, 1 min
12. STEP RESPONSE: To within 99% of full scale: 300 msec
4.20 REF
1.08
3.12
(27.5)
(106.7)
(79.2)
10
9
8
7
5
4
3
OFF = 0
DIP SWITCH SETTINGS:
2
1
ON = 1
MC2279X
ON
01100-1V 0
0-100mA
0-50mA
0-20mA
4-20mA
0-10mA
0-5mA
0-2mA
0-1mA
0-10V
0-100V
0-50V
0-20V
0-5V
1-5V
0-2V
0
0
0
0
0
0
0
0
1
1
1
1
1
10
10
0
0
1
1
1
1
0
0
0
0
11
11
1
0
1
0
1
0
1
0
1
0
0
0
001
1
1
1
0
0
0
1
10
10
1
0
0
0
0
0
0
11
11
1
0
1
0
0
1
0
0-50mV
0-100mV
0-200mV
0-500mV
0-20mV
0-20mA
4-20mA
INPUT
0-5V
0-10V
0-1mA
OUTPUT
001
0
0
9
0
000
0
0
0
0
0
0
1
0
0
1
1
7
0
6
0
8
0
1
0
0
1
10
0
5
0
0
SWITCH 1
00
0
0
0
1
1
0
1
1
34
INPUT RANGE
OUT FIELD/FACT.
IN FIELD/FACT.
OUTPUT RANGE
10
I
IN
1V
OUT+
I
OUT-
I
11 12
879
INPUT
COMM
10V
100V
VDC+
546
VDC-
213
OUT+
OUT-
V
V
20mA/1mA OUTPUT
11-36VDC
STATUS
6
*
*
T
S
U
MC2290C
S
A
T
MADE IN U.S.A.
RED LION CONTROLS
MODEL IAMA
YORK, PA.
IAMA
MODEL IAMA - UNIVERSAL SIGNAL CONDITIONING MODULE
DIMENSIONS In inches (mm)
CAUTION: Risk of Danger.
Read complete instructions prior
to installation and operation of the unit.
CAUTION: Risk of electric shock.
Bulletin No. IAMA-J
Drawing No. LP0413
Released 12/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
UL Recognized Component,
File # E179259
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1

1 3-WAY ISOLATION OF ANALOG SIGNALS UNIVERSAL CONVERSION MODULE - INPUTS AND OUTPUTS SELECTED VIA DIP SWITCH SETTINGS OVER 100 INPUT AND OUTPUT

Page 2 - BLOCK DIAGRAM

213. ACCURACY (INCLUDING LINEARITY): Factory: ±0.1% of span max. for all ranges except 1 mA, 2 mA, and 20 mV. These ranges are accurate to ±0.2% of sp

Page 3 - TABLE 3, INPUT RANGE SETTINGS

3TABLE 1, LED INDICATIONSGETTING STARTEDOne method for the Input (1 or 2 below) should be configured, and one method for the Output (3 or 4 below) sho

Page 4 - SCALING PROCEDURE

4POWER AND OUTPUT CONNECTIONSPowerPrimary power is connected to terminals 2 and 3 (labeled VDC- and VDC+). For best results, the Power should be relat

Page 5

52.1 Remove power.2.2 Connect signal source to the correct input terminals based on the maximum signal input.Terminal 7: max. signal input 1 VDCTerm

Page 6

64.1 Remove power.4.2 For voltage output scaling, go to Step 4.4. For current output scaling, continue at Step 4.3.4.3 Set 20 mA/1 mA switch (S2)

Page 7 - T Rail Installation

7The following list outlines conditions that are unique to factory recalibration:1. Unlike the field scaling procedures, there are no software under a

Page 8 - APPLICATION

MODEL IAMAOUTPUT RANGEINPUT RANGE20mA/1mA OUTPUTIN FIELD/FACT.OUT FIELD/FACT.7ON1654321098IAMASTATUSIAMAASTTUSMODEL IAMAON10920mA/1mA OUTPUTINPUT RANG