NOTES:
1. SENSOR VOLTAGE AND CURRENT
The +12 VDC (out) terminal can supply voltage to a sensor within a ±25%
variation, due to line and internal load variations. All RLC sensors will
accommodate this variation.
2. When shielded cable is used, the shield should be connected to “COMM.”
at the unit and left disconnected at the sensor end.
3. The Lead and Feedback frequency inputs can accept source pulses from
other circuits up to +28 V in amplitude. For voltages above +28 V, a limiting
resistor and zener diode should be used to limit the voltage at the input.
-38-